Main Article Content

Nieke Karnaningroem

Abstract

This research conducted to know the efficiency degradation of PV and oil content at IPAL PT Pantja Motor with addition of Santabac GC 603, in laboratory scale and field with the time detensi 1 day. Result got for the efficiency of laboratory scale without addition of Santabac GC 603 is PV 78,1-80% and also oil content 49-51%, while with the addition of Santabac GC 603 is PV 81,9-82,9 % and 78,2-80 % oil content. For the scale of field, efficiency without addition of Santabac GC 603 is 76,6-78,3 % PV and 47,1- 48,4 % oil content and also with the addition of Santabac GC 603 is 79,5-81,1 % PV and 77,1-79,4 % oil content.