STUDI KINERJA ANAEROBIC RADIAL MIXING REACTOR TERHADAP PENURUNAN KANDUNGAN COD DAN SS IPLT SUKOLILO, SURABAYA
Main Article Content
Abstract
Using a radial mixing anaerobic reactor a study was conducted to remove organics of septic tanks sludge of IPLT Sukolilo. The results showed that the granular sludge quality of the biofilm of reactor was important for the organic removal. The granular sludge must exist and grow during high organic loading. The reactor was able to remove 72.62 % and 89.64 % of COD and SS respectively at a detention time of 28 hours. The same removal of detention time of 2.8 hours was 62.64 % and 76.42 %. The reactor was able to cope with the organic shocks. The start-up process for bacterial growth was an important step to achieve such removal.
Downloads
Article Details
Pengiriman manuskrip ke Jurnal Purifikasi diartikan bahwa karya tersebut belum pernah dipublikasikan pada jurnal lain serta tidak dalam pertimbangan untuk dipublikasikan di tempat lain. Penulis dengan ini bersedia menyerahkan hak cipta manuskrip beserta isinya kepada Jurnal Purifikasi, jika diterima untuk publikasi. Manuskrip yang diterima akan dipublikasikan dalam bentuk cetak dimana ISSN terikat dalam bentuk cetak bukan dalam bentuk online (pdf). Penulis tidak diperbolehkan mempublikasikan karyanya ke dalam bentuk lain (jurnal) tanpa seizin pengelola Jurnal Purifikasi.
Dengan menyerahkan manuskrip, penulis telah dianggap mengetahui segala hak dan kewajiban yang melekat pada setiap manuskrip.