PENGARUH DEBIT LIQUID TERHADAP EFISIENSI ABSORBSI DALAM PENYISIHAN SO2 PADA SPRAY TOWER ABSORBER
Main Article Content
Abstract
One technique to eradicate SO2 contaminant is gas absorbtion system with liquid, for instance Spray Tower Absorber. The research was performed to examine changes value pH adsorber and SO2 efficiency removal within 90 minutes using solar oil 100% with initial pressure of fuel tank = 60, 80 and 100 psi; and flow, water volume, nozzle = 3,5 and 7 L/minutes. Absorber used in this experiment was 0,0006% H2O2 solution. The result shows that pressure and flow absorber affect the absorbtion efficiency for real. Initiate pressure of fuel tank that was greater within time had caused the decrease of absorbtion efficiency faster. The value of pH absorber after being used for absorbtion within 90 minutes was approximately 6,79 because of the raw water buffer originated by acidity and hardness. For efficiency more than 70%, lowest pH absorber was on range 5,59-6,25 and total recirculation for flow 3 L/minutes was maximum 17 times, flow 5 l/minutes was 34 times and for 7 l/minutes was maximum 56 times of recirculation.
Downloads
Article Details
Pengiriman manuskrip ke Jurnal Purifikasi diartikan bahwa karya tersebut belum pernah dipublikasikan pada jurnal lain serta tidak dalam pertimbangan untuk dipublikasikan di tempat lain. Penulis dengan ini bersedia menyerahkan hak cipta manuskrip beserta isinya kepada Jurnal Purifikasi, jika diterima untuk publikasi. Manuskrip yang diterima akan dipublikasikan dalam bentuk cetak dimana ISSN terikat dalam bentuk cetak bukan dalam bentuk online (pdf). Penulis tidak diperbolehkan mempublikasikan karyanya ke dalam bentuk lain (jurnal) tanpa seizin pengelola Jurnal Purifikasi.
Dengan menyerahkan manuskrip, penulis telah dianggap mengetahui segala hak dan kewajiban yang melekat pada setiap manuskrip.