RANCANG BANGUN DAN UJI KINERJA HIGH VOLUME AIR SAMPLER UNTUK MENGUKUR TOTAL SUSPENDED PARTICULATE
Main Article Content
Abstract
Total suspended particulate (TSP) is fine particles in ambient air that settles very slowly and is normally measured using High Volume Air Sampler (HVAS). A HVAS should meet several design criteria, such as air flow rate of 1.13 to 1.70 m3/min according to national standard (SNI). This research produced four HVAS units using different types of fan and air vacuum pumps, i.e. centrifugal fan, axial fan, vacuum pumps with the power of 600 Watt and 1000 Watt. During performance test, the highest flow rate in the order of 0,518 m3/min was produced by 1000 Watt vacuum pump HVAS. Comparison test between designed HVAS and the reference HVAS showed that the ambient TSP concentration was 60.3% of those measured by reference HVAS.
Downloads
Article Details
Submission of a manuscript to Jurnal Purifikasi means that the work has never been published in another journal and is not under consideration for publication elsewhere. The author hereby agrees to submit the copyright of the manuscript and its contents to Jurnal Purifikasi, if accepted for publication. Accepted manuscripts will be published in printed form where the ISSN is bound in printed form, not in online form (pdf). Authors are not allowed to publish their work in other forms (journals) without permission from the Jurnal Purifikasi manager.